Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 44(3): 574-577, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30702682

RESUMO

The extension of transient grating spectroscopy to the x-ray regime will create numerous opportunities, ranging from the study of thermal transport in the ballistic regime to charge, spin, and energy transfer processes with atomic spatial and femtosecond temporal resolution. Studies involving complicated split-and-delay lines have not yet been successful in achieving this goal. Here we propose a novel, simple method based on the Talbot effect for converging beams, which can easily be implemented at current x-ray free electron lasers. We validate our proposal by analyzing printed interference patterns on polymethyl methacrylate and gold samples using ∼3 keV X-ray pulses.

2.
Phys Rev Lett ; 114(5): 054801, 2015 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-25699448

RESUMO

The Linac Coherent Light Source has added a self-seeding capability to the soft x-ray range using a grating monochromator system. We report the demonstration of soft x-ray self-seeding with a measured resolving power of 2000-5000, wavelength stability of 10(-4), and an increase in peak brightness by a factor of 2-5 across the photon energy range of 500-1000 eV. By avoiding the need for a monochromator at the experimental station, the self-seeded beam can deliver as much as 50-fold higher brightness to users.

3.
J Synchrotron Radiat ; 20(Pt 5): 667-82, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23955029

RESUMO

The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs.

4.
J Synchrotron Radiat ; 19(Pt 5): 675-81, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22898944

RESUMO

The X-ray optics group at the Swiss Light Source in co-operation with RIT (Rigaku Innovative Technologies) have investigated seven different multilayer samples. The goal was to find an ideal multilayer structure for the energy range between 6 keV and 20 keV in terms of energy resolution and reflectivity. Such multilayer structures deposited on substrates can be used as X-ray monochromators or reflecting synchrotron mirrors. The measured reflectivities agree with the simulated ones. They cover a reflectivity range from 45% to 80% for energies between 6 keV and 10 keV, and 80% to 90% for energies between 10 keV and 20 keV. The experimentally measured energy resolution of the samples lies between 0.3% and 3.5%.

5.
J Synchrotron Radiat ; 18(Pt 2): 134-42, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21335898

RESUMO

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deliver a resolving power above 20400 at a photon energy of 930 eV (Cu L-edge). With this energy taken as reference, the VLS coefficients are optimized to cancel the lineshape asymmetry (mostly from the coma aberrations) as well as minimize the symmetric aberration broadening at large grating illuminations, dramatically increasing the aberration-limited vertical acceptance of the spectrometer. For any energy away from the reference, corrections to the entrance arm and light incidence angle on the grating are evaluated to maintain the exactly symmetric lineshape. Furthermore, operational modes when these corrections are coordinated are evaluated to maintain either energy-independent focal curve inclination or maximal aberration-limited spectrometer acceptance. The results are supported by analytical evaluation of the coma term of the optical path function. This analysis thus gives a recipe for designing a high-resolution spherical VLS grating spectrometer operating with negligible aberrations at large acceptance and over an extended energy range.

6.
J Synchrotron Radiat ; 17(5): 631-43, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20724785

RESUMO

The concepts and technical realisation of the high-resolution soft X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for resonant inelastic X-ray scattering (RIXS) and angle-resolved photoelectron spectroscopy (ARPES) are described. The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not only the light polarization (including circular and 0-180 degrees rotatable linear polarizations) but also the energy without changing the gap. The beamline optics is based on the well established scheme of plane-grating monochromator operating in collimated light. The ultimate resolving power E/DeltaE is above 33000 at 1 keV photon energy. The choice of blazed versus lamellar gratings and optimization of their profile parameters is described. Owing to glancing angles on the mirrors as well as optimized groove densities and profiles of the gratings, the beamline is capable of delivering high photon flux up to 1 x 10(13) photons s(-1) (0.01% BW)(-1) at 1 keV. Ellipsoidal refocusing optics used for the RIXS endstation demagnifies the vertical spot size down to 4 microm, which allows slitless operation and thus maximal transmission of the high-resolution RIXS spectrometer delivering E/DeltaE > 11000 at 1 keV photon energy. Apart from the beamline optics, an overview of the control system is given, the diagnostics and software tools are described, and strategies used for the optical alignment are discussed. An introduction to the concepts and instrumental realisation of the ARPES and RIXS endstations is given.

7.
Rev Sci Instrum ; 79(11): 113704, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19045892

RESUMO

We report on the successful installation and operation of a scanning transmission x-ray microspectroscope (STXM) at the PolLux facility at the Swiss Light Source. This integration of an advanced STXM with improved sample handling capabilities and a novel beamline provides unique capabilities. PolLux uses linearly or circularly polarized x-rays from a bending magnet with an extended photon energy range (200-1400 eV). It is therefore well suited to determine a sample's quantitative chemical composition, molecular orientation, or thickness of organic as well as condensed matter materials. The local magnetic state of magnetic thin films is accessible through fast helicity switching by steering the electron beam off axis through the bending magnet. Ex vacuo girder movers allow fast and highly reproducible (<1 microm) alignment of the instrument with respect to the photon beam. The present spatial resolution is approximately 20 nm, limited by the zone plates utilized. The instrument has the stability and positional resolution to operate with much higher resolution optics as it becomes available. In addition to characterization experiments, we present several typical examples from materials research and environmental science to exemplify the capabilities.

8.
J Synchrotron Radiat ; 5(Pt 3): 780-2, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263651

RESUMO

At the BESSY II storage ring, the Physikalisch-Technische Bundesanstalt (PTB) will operate insertion devices dedicated to radiometric use. One branch of the appendant beamline system will be equipped with a grazing-incidence monochromator, described here. The monochromator concept is based on a plane grating operated in parallel light; therefore exact focusing is maintained for all photon energies irrespective of the angular setting at the grating. The monochromator has been optimized for small higher-order transmittance and high power throughput, as required by radiometric applications in the wide photon energy range from 20 eV to 1900 eV.

9.
Zentralbl Gynakol ; 111(16): 1128-31, 1989.
Artigo em Alemão | MEDLINE | ID: mdl-2573223

RESUMO

Ulcerative colitis is a disease confined to the colon in an age from 20 to 40 years mainly. Fertility and pregnancy are not disturbed generally. The influence of pregnancy on the course of the colitis is not foreseeable, however. The therapy with Salazosulfapyridine is possible in pregnancy, too.


Assuntos
Colite Ulcerativa/tratamento farmacológico , Complicações na Gravidez/tratamento farmacológico , Sulfassalazina/uso terapêutico , Adulto , Feminino , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...